Electrical coil data, Mechanical data – Warner Electric Preassembled Clutch_Brake Module User Manual

Page 6

Advertising
background image

6

Warner Electric • 800-825-9050

819-0343

Figure 9

If the armature for either the clutch or the
brake is too far away from its mating friction
surface, it is possible to move this back into
adjustment using a flat head screwdriver.

This is a three-step process.

1. Simply slide the screwdriver through the

window and press the armature toward its
mating friction surface.

2. Rotate the output of the unit. The rotor

and window should stay in place when you
do this. Only the armatures will move.
Rotating the rotor will move the window.

3. Repeat steps 1 & 2 to ensure that the air-

gap between the armature and its mating
friction surface is about 1/32" and that the
armature is kept square. (If the armature is
cocked, it may engage on one rim, giving
the appearance of engagement but failing
to provide full torque.)

If a scraping sound is noted when the output
shaft is spun, it means an armature is drag-
ging. Insert a screwdriver through the vent
holes and slot in the fan and pry the dragging
armature (clutch or brake as observed) away
from the mating surface evenly all the way
around. Re-check the engagement as
described in step B of the Start-Up instruc-
tions.

Electrical Coil Data

Clutch Brake Clutch Brake Clutch Brake

Voltage–D.C.

90

90

24

24

6

6

Resistance

UM-50

452

452

31.8

31.8

1.86

1.86

(OHMS)

UM-100/180

392

392

26.7

26.7

1.81

1.81

UM-210/215

248

248

17.9

17.9

1.22

1.22

Amperes

UM-50

.199

.201

.755

.755

3.23

3.23

UM-100/180

.230

.230

.896

.896

3.31

3.31

UM-210/215

.363

.363

1.34

1.34

4.9

4.9

WATTS (17.9) UM-50

18

18

18.1

18.1

19.4

19.4

UM-100/180

20.7

20.7

21.5

21.5

20.0

20.0

UM-210/215

32.7

32.7

32

32

29.6

29.6

Build Up

UM-50

52

53

52

53

52

53

(Milliseconds) UM-100/180

72

75

72

75

72

70

UM-210/215

120

100

120

100

110

100

Decay

UM-50

6.2

5.0

6.2

5.0

6.5

5.0

(Milliseconds) UM-100/180

12

10

12

10

12

10

UM-210/215

20

10

20

10

20

10

Mechanical Data

UM-50

UM-100/180

UM-210/215

Static Torque - lb. ft.

16

30

95

Maximum Speed - rpm

3600

3600

3600

Average Weight-lbs.

1020

10

13.2

30.6/31

1040

8.3

10.3

24.3/25

2030

13

16.5

41.3/42

3040

11.3

13.6

35/35.5

Inertia - WR - lb.ft.

Configuration

50

100/180

210

215

1020 input

.021

.047

.190

.190

1020 output

.0195

.050

.193

.195

1040 input

.021

.047

.190

.190

1040 output

.0105

.027

.112

.114

2030 input

.021

.048

.198

.200

2030 output

.0195

.050

.193

.195

3040 input

.021

.048

.198

.200

3040 output

.0105

.027

.112

.114

Advertising