Warner Electric SFC-120, SFC-170, SFC-250, SFC-400 Bearing Mounted, Flange Mounted User Manual

Page 10

Advertising
background image

10

Warner Electric • 800-825-9050

P-200

• 819-0481

D. Mounting the Armature Assembly

1. SFC 250 and 400 size units.

Insert a key in the keyslot of the shaft and slide the
armature assembly onto the shaft.

2. (SFC120 do not use keyway)

Position the assembly to allow a gap of about 1/64
inch between the faces of the armature and magnet.
The overall axial dimension should be in accordance
with the dimensions specified on the illustration
drawings.

3. Secure the assembly in this position by alternately

tightening the two setscrews in the hub.

4. The hub may need to be repositioned as wear

occurs with time.

Electrical Coil Data

Unit Size

SF/SFC 120

SF/SFC 170

Voltage – DC

6

24

90

6

24

90

Resistance @ 20°C — Ohms

6.32

104

1386

6.96

111.2

1506

Current — Amperes

.949

.230

.065

.861

.215

.060

Watts

5.69

5.52

5.85

5.85

5.16

5.37

Coil Build-up — Milliseconds

12

12

11

17

17

16

Coil Decay — Milliseconds

8

8

7

8

7

6

Unit Size

SF/SFC 250

SF/SFC 400

Voltage – DC

6

24

90

6

24

90

Resistance @ 20°C — Ohms

5

76.4

1079

4.88

73

1087

Current — Amperes

1.2

.314

.084

1.23

.322

.083

Watts

7.2

7.5

7.51

7.39

7.96

7.45

Coil Build-up — Milliseconds

48

48

44

154

154

154

Coil Decay — Milliseconds

15

15

13

62

60

55

Notes: Build-up time equals current to approximately 90% of steady state value and flux to 90%.

Decay time equals current to approximately 10% of steady state value and flux to 10%.

Approximately because current leads or lags flux by a small amount.