Warner Electric SFC-120, SFC-170, SFC-250, SFC-400 Bearing Mounted, Flange Mounted User Manual

Page 43

Advertising
background image

1B

1A-1

1A

1A-3

1A-2

2-1

2-2

2-3

2

(Shipped Assembled)

2-2

2-4

2-5

2-4-1

How to Order:
1. Specify Type of Armature Desired.
2. Specify Bore Size for Item 1A-1 or 1B and Item 2.
3. Specify Voltage for Item 2.

Example:
SFC-250 Clutch Coupling per I-25523 - 90 Volt
Standard Armature
1/2" Armature Hub Bore
1/2" Rotor Bore

These units meet standards set forth in UL508 and are
listed under guide card #NMTR2, file #59164. These
units are CSA certified under file #LR11543.

Item

Description

Part Number

Qty.

1A

Armature and Hub

1A-1

Armature Hub

1

3/8" Bore

5103-541-002

1/2" Bore

5103-541-004

5/8" Bore

5103-541-006

3/4" Bore

5103-541-008

1A-2

Armature

5124-111-001

1

1A-3

Release Spring

5103-101-003

1

1B

Antibacklash Armature

1

3/8" Bore

5365-111-003

1/2" Bore

5365-111-005

5/8" Bore

5365-111-007

3/4" Bore

5365-111-009

2

Field and Rotor Assembly

1

6 Volt – 3/8" Bore

5103-452-002

24 Volt – 3/8" Bore

5103-452-004

90 Volt – 3/8" Bore

5103-452-007

6 Volt – 1/2" Bore

5103-452-016

24 Volt – 1/2" Bore

5103-452-018

90 Volt – 1/2" Bore

5103-452-021

2-1

Rotor

1

3/8" Bore

5103-751-014

1/2" Bore

5103-751-016

2-2

Retainer Ring

748-0371

2

2-3

Ball Bearing

166-0108

1

2-4

Field

1

Item

Description

Part Number

Qty.

6 Volt

5103-451-018

24 Volt

5103-451-020

90 Volt

5103-451-023

2-4-1 Terminal Accessory

5103-101-002

1

2-5

Set Collar*

266-0005

1

*Used with 1/2" Bore only.

SFC-250 Clutch Coupling Bearing Mounted

Drawing I-25523

43

Warner Electric • 800-825-9050

P-200

• 819-0481

Advertising
This manual is related to the following products: