Installation Instructions

Conduit Box Kit No. 5200-101-010
Description

This Warner Electric conduit box is designed to
provide a proper means for field wiring terminations. It
conforms to the requirements of Underwriters
Laboratories. Kit No. 5200-101-010, plus magnet
terminal accessory kit, contains all components
needed to assemble a conduit box for the above
mentioned units. Please follow these instructions
carefully when installing this conduit box. Failure to
comply with these instructions could result in unsafe
electrical con nec tions

.

Parts List for Kit 5200-101-010

Item

Quan.

Part Name

1

1

Bracket

2

1

Screw, Hex, Washer Hd.
and Sems Conical Washer

3

1

Box, Conduit

4

3

Screw, Hex. Washer Hd.

5

1

Plug, Protective

6

2

Grommet, Wire

7

2

Spacer, Terminal

8

2

Cap, Terminal

9

1

Screw, Hex. Washer Hd.

9-1

1

Terminal, Ring

10

1

Cover Assembly

*11

2

Screw No. 6 Brass

2

Screw No. 8 Brass

†12

2

Terminal, Ring

* The No. 6 screws are required on Sizes 375, 400, and 475. All

others use No. 8.

† Terminal Ring provided with terminal accessory kit 5311-101-003,

5311-101-001 respectively, supplied with magnets.

Note: All mounting screws are self-tapping.