Mechanical data, Troubleshooting - mechanical, Enclosed electro-module options – Warner Electric Gen 2 Electro-Module EM-50, EM-100, EM-180 User Manual

Page 11: Electrical coil data

Advertising
background image

11

Warner Electric • 800-825-9050

819-0529

If power is present in the proper voltage and
current, then skip ahead to the Mechanical
Troubleshooting Section.

If power is not present, inspect the lead
wires for breaks or cuts.

If the wires are intact, the problem may be
with the power supply or the switch.

Using a voltmeter, check to see that voltage
is leaving the power supply and that the
switch is sending power to the clutch or
brake.

Finally, if there is no power leaving the
switch or power supply, check the incoming
AC power to insure that it is reaching the
power supply.

Troubleshooting - Mechanical

A likely mechanical cause for a clutch or brake
not engaging when DC power is applied is that
the airgap between the friction faces is too
large. When power is applied to an Electro-
magnetic clutch/brake, the unit magnetically
clamps the friction faces together. An airgap that
is too large can keep the unit from clamping
together. If the airgap is too small the faces will
rub all of the time.

To adjust the airgap, see Section C on page 5.

Enclosed Electro-Module Options

Vented Warner Electric Electro-Module and
base assemblies can be oriented as necessary
to keep contaminates from entering the open
housing vents.

If an Enclosed Electro-Module (10-20, 10-40,
20-30, 30-40, 10-20FBC, 20FBC-30) is required
an optional Cover Kit, Warner Electric part
number 5370-101-076, can be purchased
separately to enclose the open vents in the
housing. Each Cover Kit includes two (2) vent
covers and four (4) screws needed to convert a
vented Electro-Module to an enclosed design
(non-washdown) as shown in Figure 12a.

Electrical Coil Data

Clutch

Brake

Clutch

Brake

Voltage-D.C.

90

90

24

24

Resistance

EM-50

452

429

31.8

28.8

(OHMS)

EM-100/180

392

308

26.7

21.7

Current

EM-50

.20

.21

.76

.83

Ampheres)

EM-100/180

.23

.29

.90

1.1

Power

EM-50

18

19

19

20

(WATTS)

EM-100/180

21

27

22

27

Coil Build Up EM-50

52

40

52

40

Time (ms)

EM-100/180

72

80

72

80

Coil Decay

EM-50

6

5

6

5

Time (ms)

EM-100/180

12

8

12

8

Mechanical Data

EM-50

EM-100/180

Static Torque - lb. ft.

16

30

Maximum Speed - rpm

3600

3600

Average Weight - lbs.

20

9.2

11.2

10-20

15.6

18.7

10-40

14.0

16.6

20-30

18.4

21.7

30-40

16.8

19.5

Inertia - WR - lb.ft.

2

Configuration

50

100/180

20 output

.0195

.050

10-20 input

.021

.047

10-20 output

.0195

.050

10-40 input

.021

.047

10-40 output

.0105

.027

20-30 input

.021

.047

20-30 output

.0195

.050

30-40 input

.021

.048

30-40 output

.0105

.027

Advertising