4 Warner Electric • +33 (0) 2 41 21 24 24

P-2098-WE-A4

This installation and Operating Manual has been arranged for the systematic installation and start-up of your Tension
Control System. Please check off each step before proceeding to the next step.

SYSTEM WIRING AND SETTING:

WARNING:

Contact with electrical voltages present in the driver covered in this manual can cause injury. To avoid these

consequences, make sure all power is off during installation.

These wiring precautions will help you properly install and wire a trouble-free system.

1. Use proper gauge wire for all pin :

• Data input : 0,5mm² (20AWG) or 0,75mm² (18AWG)

• Brakes wires : 0,75mm² (18AWG) or 1mm² (17AWG)

2. Shielded cable is recommended for all connections.

3. Do not use this driver for purposes other than those intended. Such use could damage the driver.

WIRING:

Figure 2: X2DRV wiring—one or two brakes

1. Wire 24V DC input power to pin 24V as shown in Figure 3.

Figure 3: Power supply wiring

2. Connect wiring from brake magnets to Pin BK1 and/or BK2 of the X2DRV as shown in Figure 2.

3. Select the Input type with the red switches located along the bottom of the control:

CAUTION

:

Improperly setting the

24VDC can damage the power
supply and/or the driver

Advertising