Discrimination Detailed

• Visual Reject - When selected (“X”in box), rejected VDI numbers do not appear on the display. This

reduces the number of VDI numbers that appear allowing better concentration on those accepted. When not
selected (empty box), all VDI numbers appear on the display (rejected and accept) whenever a target is compatible
with that VDI number.

• Select DISCRIMINATION and press ENTER.

• ARROW to Visual Reject.

• Press ENTER to select (“X”) or de-select (empty square) Visual Reject.

• V.D.I. Selected By – Allows four very different methods of adjusting the Accept and Reject (discriminate)

status of the VDI target scale. The method chosen automatically appears on the Live Control and Six Block Menu.

• Level - Provides a simple linear setting (similar to a knob adjustment) increasing

or decreasing discrimination.

• ARROW to VDI Selected By and press ENTER. ARROW to Reject and

press ENTER.

• Use ARROW Left & Right to set the VDI number. All VDI numbers at or below

(lower numbers) are rejected and all VDI numbers above (greater than) are

accepted.

• Icons – Select discrimination accept / reject by the current program icon scale.

• ARROW to Icon and press ENTER. ARROW to EDIT and press ENTER.

• ARROW among current Icons for that program, “X” = accept that Icon range

of VDI numbers, Empty square = reject that Icon VDI range.

• Press ENTER to change each Icon range accept or reject.

• Squeeze and release toggle on grip to exit.

• VDI – Select discrimination accept/reject by traditional individual VDI number.

• ARROW to VDI and press ENTER. ARROW to EDIT and press ENTER.

• ARROW to view current program VDI numbers accept or reject status.

“X” = accept, empty square = reject.

• Press ENTER to change highlighted VDI number between accept/reject.

• Hold ENTER then ARROW to drag current accept/reject status through

multiple VDI numbers (block edit).

• Squeeze and release toggle on grip to exit.

• Graph –Select discrimination accept/reject by using a graph.

• ARROW to Graph and press ENTER. ARROW to Edit and press ENTER.

• Use ARROW Left & Right to view the current Program accept and reject

settings accompanied with both the VDI number and icon.

• Straight green line = accept, red dip = reject.

• Press ARROW Up & Down to change accept or reject for each VDI number.

Icon is used for reference.

• Squeeze and release toggle to exit.

Advertising