Seite21, Connectors, Troubleshooting – WolfVision VZ-35 User Manual

Page 21

Advertising
background image

21

CONNECTORS

1 2 3 4 5 6 7 8 9 10 11 12 13

14 15 16 17 18 19 20 21 22 23 24 25

Serial port

(9-pin D-Sub)

Function: ASCII :

Image on 192
Iris open 193
Focus plus 194
Zoom wide 195
Image off 196
Iris close 197
Focus minus 198
Zoom near 199
Power on 200
Power off 201
Preset 1 202
Preset 2 203
Light on 204
Light off 205
Menu (first use 218!) 206
Display / BARS 207
Function up 208
Function down 209
Data up / white 210
Data down / black 211
Save preset 1 216
Save preset 2 217
Unlock menu 218
Switch IR-mode A/B 221
Preset max. wide 229 *
Preset A4 230 *
Preset A5 231 *
Preset A6 232 *
Preset A7 233 *
Preset A8 234 *
Preset max. tele 235 *

* = these functions are only available
on Visualizers with serial number
353200 and higher

Y/C cable cable (7-pin to 4-pin):

Parallel port: (25-pin D-Sub, 24 V)

Serial port: (9-pin D-Sub)

1. Y-signal
2. Y-ground
5. C-signal
6. C-ground
3, 4 and 7 not connected

3. Y-signal
1. Y-ground
4. C-signal
2. C-ground

1. Image on
2. Iris open
3. Focus plus
4. Zoom far
5. Power on
6. Preset 1
7. Light on
8. -
9. Menu

10. Function up
11. Data up/White
12. Save
13. GND
14. Image off
15. Iris close
16. Focus minus
17. Zoom near
18. Power off

19. Preset 2
20. Light off
21. -
22. Display / Bars
23. Function down
24. Data down
25. -

(male - front side)

(male - front side)

Pins: 2: RX, 3: TX, 5: GND, 7: RTS, 8: CTS

Baud rate

: 19200, databits: 8, stopbit: 1, parity: no

Between sending codes should be a break of 250ms minimum !

TROUBLESHOOTING

Symptoms:

Check points:

No power

- Is a power cord connected?
- Is the main power switch (# 34, on the back of the unit) switched to "I"?
- Check fuse! (#35)! (see page 11)

Bright and hazy spots in the picture

- Is the mirror on the reflector head (#10) or the glass dirty?
If yes clean it BUT BE CAREFUL - SEE PAGE 12

Low light

- Is the lamp worn out?
- Are you using the Visualizer with the correct voltage?
- Is the lamp correctly placed in the socket?
- Check the lamp change slot (#9). Is the black metal plate fixed? (see page 10).

No light

- Is the light switched off (LIGHT keys #26,#27)?
- Is the lamp-changer (#8) in the right position?
- Is the lamp burned out?
- Is the light slot covered?

Please note that ASCII-Codes must be
sent as one byte. (e.g. "199" and not
"1" + "1" + "9")

1

6

2

7

5

3

4

(connectors viewd from front side)

3

4

1

2

Advertising