3.1 In s ta lla tio n P re c a u tio n s

During installation, be aware of the precautions below:

Read the user manual: The user manual provides a complete description of

the TANK-720, installation instructions and configuration options.

DANGER! Disconnect Power: Power to the TANK-720 must be

disconnected during the installation process, or before any attempt is made to

access the rear panel. Electric shock and personal injury might occur if the

rear panel of the TANK-720 is opened while the power cord is still connected

to an electrical outlet.

Qualified Personnel: The TANK-720 must be installed and operated only by

trained and qualified personnel. Maintenance, upgrades, or repairs may only

be carried out by qualified personnel who are familiar with the associated

dangers.

Air Circulation: Make sure there is sufficient air circulation when installing the

TANK-720. The TANK-720’s cooling vents must not be obstructed by any

objects. Blocking the vents can cause overheating of the TANK-720. Leave at

least 5 cm of clearance around the TANK-720 to prevent overheating.

Grounding: The TANK-720 should be properly grounded. The voltage feeds

must not be overloaded. Adjust the cabling and provide external overcharge

protection per the electrical values indicated on the label attached to the back

of the TANK-720.

3.2 Ha rd Dis k Drive (HDD) In s ta lla tio n

To install the hard drive, please follow the steps below:

S te p 1:

Remove the bottom panel by removing the 10 retention screws from the bottom

panel (Figure 3-1).