Operation, Automatic system start-up, Overtime system start-up – Lincoln Electric IM10109 CIRCULATOR User Manual

Page 23: Plc start-up process, Set weekly timer

Advertising
background image

B-7

OPERATION

B-7

AUTOMATIC SYSTEM START-UP

1. Follow Set Weekly Timer procedure.

OVERTIME SYSTEM START-UP

1. Press Overtime button.

a. Pressing button will override system to run

an additional 10 hours.

PLC START-UP PROCESS

1. Press

to show time and date.

2. Press ESC.
3. Select ʻStartʼ..: Press

or

.

a. If “Stop” is the first item displayed, system

is already in START mode.

b. Press ESC.

4. Confirm “Start”: Press OK.
5. Press ESC.

SET WEEKLY TIMER

There are four week timers (Timer 1 thru 4) installed
in the program, each consisting of three screens.

To change the timer settings, proceed as follows. This
procedure can be executed via the PLC display on the
outside of the control panel.

1. Press

to show time and date.

2. Press ESC.
3. Select ʻSet Paramʼ: Press

or

.

4. Press OK.

5. Press

or

to change cursor position. Press

or

to change value.

6. Press OK.

NOTE: Timer 1 - screen 4: make sure setting

Pulse = Off.

If desired, Timers 2 to 4 can be used to set
additional on/off moments of the fan, resulting
in a start up of the filter cleaning process.

7. Press

several times until Timer 2 shows up. Set

additional time settings.

8. Press ESC (3) three times to return to the date and

time screen.

Press Start.

Press STOP in case of emergency. See
Troubleshooting Section
in this manual.

CIRCULATOR

FIGURE B.4

S

F1

F2

F3

F4

ESC

OK

LOGO! TD