GENERAL DESCRIPTION

The Circulator system is self contained and is specifi-
cally designed for the filtration and general removal of
welding fume. It is suitable for continuous use in
welding applications. The system features a control
panel, a filter, a fan powered by a three phase motor
and duct work.

Ambient re-circulated air enters the system through an
air inlet module located on the top of the filter unit.
The air is cleaned by the main filter cartridges and is
blown back into the workshop environment through
adjustable nozzles on the outlet unit.

NOTE: Unshaded areas of Block Logic

Diagram are the subject of discussion

F-1

THEORY OF OPERATION

F-1

CIRCULATOR

FIGURE E.1 BLOCK LOGIC DIAGRAM

PRESSURE

TRANSMITTER

CONTROL

PANEL

3 PHASE

MOTOR/

FAN

20-50 HZ

480

VA

C 3 PHASE

24 V

AC

SIGNAL

AIR FILTER

FIL

TERED AIR

EXTERNAL

COMPRESSED

AIR SUPPLY

24VDC

FILTER

CONTROL

BOX

MONITOR

AIR

FIL

TER AIR PRESSURE

DIFFERENTIAL SIGNAL 0-10

VDC (4-20ma)

C

OMPRESSED AIR

MONIT

OR SIGNAL

SOLENOID

AIR

AIR FILTER PRESSURE

DIFFERENTIAL LINES

24 VAC

SIGNAL

0-10

VDC

4-20 ma CONTROL SIGNAL

AIR

INLET

SILENCER

DUCT

OUTLET

UNIT

AIR FL

OW

Advertising