Setup menu features parameter, Definition – Lincoln Electric IM10180 POWER FEED 25M NNS User Manual
Page 36
B-21
OPERATION
POWER FEED™ 25M NNS
The Setup Menu gives access to the Setup Configuration. Stored in the setup configuration are user parameters
that generally only need to be set at installation. The parameters are grouped as shown in the following table.
SETUP MENU FEATURES
PARAMETER
P.1
through
P.99
P.101
through
P.199
P.501
through
P.599
DEFINITION
Unsecured Parameters (always adjustable)
Diagnostic Parameters (always read only)
Secured Parameters (only accessible through a p.c. or palm application)
GTAW (TIG) WELDING
The POWER FEED™ / Power Wave system is excel-
lent for Touch Start TIG welding.
The system supports TIG torches with or without gas
control valves. TIG torches with gas control valves
connect directly to the gas flow regulator. For TIG
torches without gas control valves, connect the output
gas hose on the wire feeder to the TIG torch gas
hose.
The wire feeder gas solenoid may be enabled or dis-
abled by parameter P.8 in the set-up menu found in
this operations section.