Warning safety precautions – Lincoln Electric IM10180 POWER FEED 25M NNS User Manual

Page 50

Advertising
background image

D-1

ACCESSORIES

POWER FEED™ 25M NNS

ELECTRIC SHOCK can kill.

• Do not operate with covers

removed.

• Turn off power source before

installing or servicing.

• Do not touch electrically hot

parts.

• Turn the input power to the welding power

source off at the fuse box before working in the
terminal strip.

• Only qualified personnel should install, use or

service this equipment.

WARNING

SAFETY PRECAUTIONS

ROUTINE MAINTENANCE

• Check weld cables, control cables and gas hoses

for cuts.

• Clean and tighten all weld terminals.

PERIODIC MAINTENANCE

• Motor Brushes:

Inspect the motor brushes every 6 months or every
2.5 million arc starts (whichever comes first).
Replace the brushes if they are less than 0.5” (12.7
mm) long.

CALIBRATION SPECIFICATION

All calibrations are factory set on the POWER FEED™
25M NNS.

To verify the wire feed speed:

• Assemble a .045 (1.2mm) drive roll kit into the

POWER FEED™ 25M NNS.

• Load a spool of .045 (1.2mm) electrode and thread

the electrode through the wire drive.

• Adjust the wire feed speed to 300 in/min

(7.62m/min).

• Press the COLD FEED switch and measure the

actual wire feed speed with a calibrated wire feed
speed tachometer.

• The measured wire feed speed should be within 2%

of the set value.

To verify the voltage display:

• Set the welding power source and POWER FEED™

25M NNS to a CV procedure that gives steady
"spray" transfer in the arc.

• While a weld is being made, measure the voltage

from the feed plate to work with a calibrated volt
meter.

• The displayed voltage on the POWER FEED™ 25M

NNS should be within 2% of the measured value.