Pvm - pg24 – Poly-Tex Poly-Vent (Retrofit) User Manual

Page 24

Advertising
background image

24

Q. How much time does it take to inflate and/or deflate the Poly-Vent?

A. The length of time necesary to inflate or deflate the Poly-Vent is variable depending on several factors. Length of

Poly-Vent, height of Poly-Vent, and the number and location of the blowers connected to the Poly-Vent. Obviously,
the longer the Poly-Vent, the more time is necessary to inflate and deflate. The same applies to different Poly-Vent
heights. A Poly-Vent II (single stage) system will take more time to inflate or deflate than a Poly-Vent III (two-stage)
system due to the fact that all the air must pass through more tubes and enter and exit through just one blower.

F.A.Q.

Blower fan does not rotate

No power to motor

Check power source (most often the cicuit panel).

Obstruction in blower

Turn off power source and check blower for debris.

Damaged blower

Replace the blower.

Thermostat set too high

Adjust the thermostat to a lower temperature.

Blower "hums" but fan does

Incorrect voltage

Check power source for correct voltage.

not rotate

Obstruction in blower

Turn off power source and check blower for debris.

Blower fan rotates but

Faulty flex tube

Check flex tube for damage or obstructions.

Poly-Vent does not inflate

Poor flex tube connection(s)

Check connection around air transfer gaskets for leaks.

Poly-Vent does not inflate

Air leaking somewhere in the

Check for holes or tears in Poly-Vent and repair with

completely

Poly-Vent

Poly Patch tape.

Water accumulation in Poly-Vent

If water should accumulate, it might accumulate in just

one of the tubes. Make a 1/2" to 1" slit where the water
has accumulated and drain the water. Repair the slit
with Poly Patch tape.

Poly-Vent III only:

Thermostat not wired correctly

Remove pink wire from the thermostat to the top

Top blower shuts off before

to blower motor

blower motor and attach to the lower blower motor.

the bottom blower

Remove the red wire from the lower blower motor and

attach to the top blower motor.

Advertising