Troubleshooting chart – Powermate VPF1080318 User Manual

Page 17

Advertising
background image

200-2705

17

Note: Troubleshooting problems may have similar causes and solutions.

Close drain valve

Tank drain valve is open

Check fittings with soapy water. Tighten or reseal leaking fittings.
DO NOT OVERTIGHTEN.

Fittings Leak

Clean or replace air filter element.

Restricted air intake

Decrease amount of air used.

Prolonged excessive use of air

Check air requirement of accessory. If it is higher than CFM and
pressure supplied by compressor, you need a larger compressor.
Most accessories are rated at 25% of actual CFM while running
continuously.

Compressor not large enough

Check and replace if necessary.

Hole in air hose

Immediately replace tank. DO NOT attempt to
repair.

Tank leaks

Replace compressor assembly.

Valve leaks

Replace compressor assembly.

Leaking or worn piston

Replace compressor assembly.

Blown seals

Replace regulator or internal parts.

Dirty or damaged regulator
internal parts.

If pressure drops too low, adjust regulator while accessory is used.

This is normal

Check air requirement of accessory. If it is higher than CFM and
pressure supplied by compressor, you need a larger compressor.
Most accessories are rated at 25% of actual CFM while running
continuously.

Compressor not large enough

SOLUTION

POSSIBLE CAUSE

Low pressure or not
enough air
or
Compressor does not
stop

Air leaks from regulator,
or regulator does not
regulate pressure
Regulated pressure
gauge reading drops
when air accessory is
being used

PROBLEM

WARNING

:

Replace pressure switch

Tank pressure exceeded normal
operating pressure

Replace pressure switch

Pressure switch stuck

Motor will start automatically when tank pressure drops below
kick-in pressure of pressure tank.

Tank pressure exceeds preset
pressure switch limit

Let motor cool off and overload switch will automatically reset. This
may take several minutes.

Motor overload protection has
tripped

• Replace blown fuse or resed circuit breaker. Do not use fuse or

circuit breaker with higher rating than specified for your branch
circuit.

Fuse blown or circuit breaker
tripped

• Check for proper fuse; “Fusetron” type T is acceptable.
• Check for low voltage and proper extension cord size.
• Disconnect other applications from circuit. Operate compressor

on a dedicated circuit.

Remove and clean or replace.

Check valve stuck open

Bleed line by moving pressure switch lever to OFF Position before
restarting. If bleeder valve does not open, replace bleeder valve.

Pressure bleeder valve on
pressure switch has not
unloaded head pressure

Check for proper gauge and extension cord length.

Wrong wire gauge in cord or
excessive extension cord length

Contact authorized service center.

Loose electrical connections

Contact authorized service center.

Possible defective capacitor

Have checked at service center. Do not operate compressor in the
paint spray area

Paint spray on internal motor
parts

Have checked at service center.

Possible defective motor

Pressure relief valve
opens

Motor will not run

TROUBLESHOOTING CHART