„ 3-Position Enable Switch Output Interface

The switch provides three positions: A position where the switch is not pressed (released), a
position where the switch is pressed to the intermediate position, and a position where the switch
is pressed to the innermost position (fully pressed).

When the switch is set at each position, ON/OFF status of the ENB0 to ENB1 signals are as
follows:

„ Emergency Switch Output Interface

Cable Color/

Marking Color,

Number

Signal

Name

Description

Blue/Black 2

ENB0A

3-position enable switch 0A (a-contact:normally open)
Rating: DC30V, 700 mA (Minimum applicable load: DC3V, 5mA)

Blue/Black 3

ENB0B 3-position enable switch 0B (a-contact:normally open)

Blue/None

ENB1A

3-position enable switch 1A (a-contact:normally open)
Rating: DC30V, 700 mA (Minimum applicable load: DC3V, 5mA)

Blue/Black 1

ENB1B 3-position enable switch 1B (a-contact:normally open)

The switch is not pressed.

The switch is pressed to

the intermediate position.

The switch is pressed to

the innermost position.

*1

*1 The contact is OFF when the switch is fully depressed and then returned to the released position.

ENB0

0 (OFF)

1 (ON)

0 (OFF)

ENB1

0 (OFF)

1 (ON)

0 (OFF)

Cable Color/

Marking Color,

Number

Signal

Name

Description

Purple/Black 2

EMG0A

Emergency switch 0A (a-contact:normally open)
Rating: DC30 V, 1 A (Minimum applicable load: DC5 V, 1 mA)

Purple/White 3

EMG0B

Emergency switch 0B (a-contact:normally open)

Purple/Black 1

EMG1A

Emergency switch 1A (b-contact:normally closed)
Rating: DC30 V, 1 A (Minimum applicable load: DC5 V, 1 mA)

Purple/White 2

EMG1B

Emergency switch 1B (b-contact:normally closed)

Purple/None

EMG2A

Emergency switch 2A (b-contact:normally closed)
Rating: DC30 V, 1 A (Minimum applicable load: DC5 V, 1 mA)

Purple/White 1

EMG2B

Emergency switch 2B (b-contact:normally closed)

ENB1A

ENB0A

ENB0B

ENB1B