• Turning ON GP unit with the key switch

• When the key is not turned to ON or OFF, either the “KEY_NO” or the “KEY_NC” signal is

ON. These signals will not simultaneously turn OFF.

• These signal lines must be disconnected (NC) when a GP unit without a key switch is used.

2.

Connecting the GP Unit

‹ Attachment

(1) Before connection, remove the cable's connector cap and GP3000H connector cover.

To remove the cable's connector cap, pull out the cable by holding the cable connector as
shown.

• To disconnect this cable from the connector cap, be sure to hold the cable connector and pull

it out. If you hold other parts of this cable (lock ring, etc.), the cable cannot be disconnected.

(2) Insert the cable connector to the GP3000H cable connector until it clicks. Match the S

points and insert the cable connector, as shown below.

• Be sure to insert the cable connector as shown. Failure to do so might result in damage to the

connector.

DC24V

GP

OFF

ON

KEY_NO

KEY_NC

GP3000H Cable

Pull out the cable by holding the cable connector.

connector cap

Match the

S

points and insert the cable

connector until it clicks.