7

• Tightening the screws with too much

force can damage the ST unit’s plastic
case.

• The necessary torque is 0.5N

•m.

Wiring

y To avoid an electric shock, prior to

connecting the ST unit’s power cord
terminals to the power terminal block,
confirm that the ST unit’s power supply is
completely turned OFF, via a breaker, or
similar unit.

y Any other power level can damage both

the ST and the power supply.

y When the FG terminal is connected, be

sure the wire is grounded.

1.

Wiring the DC type power supply
cable

„ Power Cord Specifications

Use copper conductors only.

„ Power Connector (Plug) Specifications

• The power connector (plug) is CA5-

DCCNM-01 made by Pro-face or
MSTB2,5/3-ST-5,08 made by Phoenix
Contact.

Insertion Slot Recess

Hook the fastener on the
Recess,

Panel

Installation Fastener

ST

Hook

and secure the fastener
on the panel with a
screw.

Power Cord
Diameter

0.75 to 2.5mm

2

[0.0009 to 0.0097 inch

2

]

(18 - 12 AWG)

Conductor
Type

Simple or Stranded Wire

*1

*1 If the Conductor’s end (individual) wires are

not twisted correctly, the end wires may either
short against each other, or against an
electrode.

Conductor
Length

+

24V

-

0V

FG

Grounding
Terminal
connected
to the ST
chassis

7 mm
[0.28in]

Insertion
Direction

+
-
FG

Advertising