Characteristics

38

Environmental Characteristics

Characteristics

NOTE: IEC 61131-2 and IP65 are not part of UL certification for hazardous locations.

Characteristics

Value

Standards

Degree of Protection

IP65

EN/IEC 61131-2

Pollution Degree

For use in Pollution Degree 2 environment

EN/IEC 61131-2

Surrounding Air Temperature
during Operation

0...50

°C (32...122 °F)

EN/IEC 61131-2, UL 508

Storage Temperature

– 20...60

°C (– 4...140 °F)

IEC 60068-2-2 tests Bb and Ab,
IEC 60068-2-14 tests Na and
EN/IEC 61131-2

Operating Altitude

2,000 m (6,560 ft) max

EN/IEC 61131-2

Vibration

IACS E10 and EN/IEC 60068-2-
6 Fc

Operation (continuous)

2...9 Hz: 1.5 mm
9...200 Hz: 4.9 m/s

2

5...8.4 Hz: 1.75 mm
8.4...150 Hz: 4.9 m/s

2

Operation (occasional)

2...9 Hz: 3 mm
9...200 Hz: 9.8 m/s

2

5...8.4 Hz: 3.5 mm
8.4...150 Hz: 9.8 m/s

2

Marine Certification
(continuous)

3...13.2 Hz: 1 mm (0.04 in.)
13.2...100 Hz: 6.86 m/s

2

Shock Resistance
(in operation)

147 m/s

2

for a duration of 11 ms

IEC 60068-2-27 Ea test

Surrounding Air Humidity
during Operation

10...85 % RH (Wet bulb temperature: 29

°C

(84.2

°F) max. - no condensation)

EN/IEC 60068-2-78 Cab

Storage Humidity

10...85 % RH (Wet bulb temperature: 29

°C

(84.2

°F) max. - no condensation)

EN/IEC 60068-2-30 Db

Electromagnetic Compatibility
(EMC)

Immunity to High Frequency Interference

EN/IEC 61131-2, IEC 61000-4-x

Electromagnetic Emissions Class A

EN 55022, EN 55011