Proface APL3000B - Node Box PC User Manual

Page 36

Advertising
background image

Chapter 2 Specifications

2-13

Switch

No.

Description

ON

OFF

Notes

1

Used for the system.

Reserved

Reserved

Factory Settings: ON

2

Used for the system.

Reserved

Reserved

Factory Settings: OFF

3

Used for the system.

Reserved

Reserved

Factory Settings: OFF

4

Cancellation function of pushing
two points on the touch panel

*1

.

*1

When two points are pushed, it is considered that middle point between the two points is

touched according to the nature of the analog resistive touch panel.

When the switch, etc. is set on the middle point, it will be enabled and may operate.

To prevent such a switch from malfunction in case of pushing two points, turn ON the SW No.4

in advance, then the middle point will be disabled to be touched.

Enabled

Disabled

Factory Settings: OFF
The middle point is not
considered to be touched
when the SW is Enabled. It is
considered to be touched
when the SW is Disabled.

5

Used for the system.

Reserved

Reserved

Factory Settings: OFF

6

Changes Reset SW mode.

Power
button

Reset SW

Factory Settings: OFF

7

Used for the system.

Reserved

Reserved

Factory Settings: OFF

8

Changes COM2 (RI <---> +5V).
(enabled only when RS-232C
mode)

+5V Output

RI

Factory Settings: OFF

9

Changes a Master/Slave setting for
Primary CF card Interface.

Slave

Master

The factory settings depend
on your selected built-in
accessory.

10

Used for the system.

Reserved

Reserved

Factory Settings: OFF

Table 1) System Set Switches

Switch

Number

Description

ON

OFF

RS-232C

RS-422

RS-485

1

Changes COM2's
communication
method

RS-232C

RS-422 / RS-485 ON

OFF

*1

OFF

*1

2

Changes COM2's
communication
method

RS-422 / RS-485 RS-232C

OFF

ON

ON

3

Changes COM2's
communication
method

RS-422 / RS-485 RS-232C

OFF

ON

ON

Advertising