Specification – Yokogawa 202 Field Mounting Rate Totalizer User Manual

Page 10

Advertising
background image

Specification

6

2. SPECIFICATION

General

Display:

LCD which is continuously powered.

Resettable Total:

7 digits with 10mm (0.4") high digits. Resettable
from front panel.

Accumulated Total:

Displayed when the ACCUM TOTAL button is
pressed.

Rate:

4½ digits with 8.5mm (0.33") high digits.

K-factor:

The pulses per unit of measure (eg. pulses/gallon)
is programmable in the range 0.000001 to
999,999.

Decimal Points:

Decimal point positions are fully programmable
for both rate and total.

Timebase:

Rate can be displayed in units per second, minute,
hour or day.

Frequency Range:

0.01Hz to 10kHz.

Signal Type:

Link settable for sinewave (15mV P-P minimum),
open collector, reed switch, pulse or Namur
proximity switch.

Battery Powered Version

Type:

Two lithium battery packs.

Battery Life:

5 years typical.

Loop Powered 4-20mA Output Version

Scale:

The 4mA and 20mA points are programmable.

Resolution and Linearity:

0.05% of span.

Accuracy:

0.05% of span at 25°C.
0.1% (typ) of span, full temperature range.

Update Time:

0.5 second.

Connection:

Two-wire.

Loop Power Supply:

9-28 Volts.

Supply Backup:

Lithium battery.

Advertising