changeAOPWMDataMX

Syntax

int changeAOPWMDataMX(MXAOPWMData * pMXAOPWMData, int aopwmNo,
int bValid, int iAOPWMValue);

Declaration

Public Declare Function changeAOPWMDataMX Lib "DAQMX"(ByRef
pMXAOPWMData As MXAOPWMData, ByVal aopwmNo As Long, ByVal
bValid As Long, ByVal iAOPWMValue As Long) As Long

Parameters

cMXAOPWMData

Specify AO/PWM data.

aopwmNo

Specify the AO/PWM data number.

bValid

Specify the boolean value.

iAOPWMValue

Specify the output data value.

Description

Changes the data of the specified AO/PWM data.
• If the constant for “Specify all AO/PWM numbers” is specified for the AO data

numbers, all AO data are changed.

• If the AO/PWM data number is outside of the range and invalid, the specification

is discarded.

• The output data specifies the changed value of the actually output value.

• Completes normally.

Return value

Returns an error number.

Reference

CDAQMXAOPWMData::getMXAOPWMData
CDAQMXAOPWMData::setAOPWM

5.1 Details of Functions - MX100 (Visual C/Visual Basic) -