Chart 6 - Troubleshooting continued

SYMPTOMS

J. Floating fl ame.

K. Burner won't turn off.

L. Rapid burner cycling.

M. Not enough heat.

POSSIBLE CAUSES

1. Blocked heat exchanger.
2. Insuffi cient combustion air.

3. Blocked venting.

4. Air leak into combined

chamber, draft hood, or fl ue

collector.

1. Poor thermostat location.

2. Defective thermostat.
3. Improper thermostat or
transformer.
4. Short circuit.

5. Defective or sticking gas valve.

6. Excessive gas supply
pressure.

1. Loose electrical connections at
gas valve or thermostat.
2. Excessive thermostat heat
anticipation.

3. Unit cycling on high limit.

4. Poor thermostat location.

1. Incorrect gas input.
2. Heater undersized.

3. Thermostat malfuction.
4. Heater cycling on limit control.

5. Check outside dampers if
used.

CORRECTIVE ACTION

1. Clean heat exchanger.
2. Clean combustion air inlet
openings in bottom panel.

Refer to installation.

3. Clean fl ue. Refer to
installation.
4. Determine cause and repair

accordingly. Refer to

installation.

1. Relocate thermostat away
from

drafts.

2. Replace thermostat.
3. Check wiring diagrams.

4. Check operation at valve.

Look for short and correct

(such as staples piercing

thermostat

wiring).

5. Replace gas valve.

6. Refer to operation.

1. Tighten all electrical
connections.
2. Adjust thermostat heat

anticipation for longer cycles.

Refer to operation.

3. Check for proper air supply
across heat exchanger.
4. Relocate thermostat. (Do not

mount thermostat on unit).

1. Refer to operation.
2. This is especially true when

the heated space is enlarged.
Have the heat loss calculated
and compare to the heater
output (80% of input). Your
gas supplier or installer can
furnish this information. If
heater is undersized, add
additional heaters.

3. Replace thermostat.
4. Check air movement through

heat exchanger. Check

voltage to power venter motor,
clean power venter wheel and
heat exchanger, and oil power
venter motor. Check fi lters,

replace if necessary.

5. Adjust dampers accordingly.