TROUBLESHOOTING (Continued)

Fault

Probable Cause

Solution

Compressed air supply does
not meet specified
requirements of ISO 8573-1:
2001 Class 3.-.3
It is not allowed to feed
liquid/aerosol/condensate
water or oil into NTO-200.

Check the following:
1.) Compressor operating correctly
and fully maintained.
2.) No contaminants near
compressor's intake.
3.) Compressed air system has
suitable filtration and is correctly
maintained.

Inlet pressure too low or too
high.

Ensure inlet pressure is within limits
specified under “Technical
Specification” section.

Reduced Purity of
nitrogen

Cartridge nearing end of life.

Replace cartridge

Internal blockage

Contact NTO-200 supplier.

Cartridge not installed
correctly.

Ensure cartridge correctly fitted in grip

Tire pressure does
not fall when
ON/OFF button
held in.

Internal fault

Contact NTO-200 supplier.

Cartridge not installed
correctly.

Ensure cartridge correctly fitted in grip

Pressure
continually high.

There is internal component
fault

Contact NTO-200 supplier.