8.11

Flow Switch Circuit Test:

1. First confirm visually that the flow switch reed clamps have not been

dislodged during handling or installation. The clamps must be fully located

within their flow switch body groove as shown.

2. To carry out the following test you will need to obtain a magnet, a typical fridge

magnet is suitable.

3. Ensure the power supply is switched on.

4. Position the magnet directly in front of the reed clamp as shown. If pump

does not start, then slowly move the magnet up and down to a position that

exceeds the extent of the reed clamp. The pump should instantaneously start

at some point during this extent of movement. If this does not happen, this

indicates a possible fault with the reed switch or the P.C.B which is located

within the terminal box. These should be checked electrically. Consult Stuart

Turner for further instructions.