Fig. 6 gasket installation, Battery replacement instructions, Models with horn (sti-1100 series) – STI 1102 User Manual

Page 6: Side view, All models end view, Depth chart for sti stopper ii, View of relay contact, Exploded electronic view

Advertising
background image

- 6 -

SIDE VIEW

6.2 in.(158mm)

MODELS WITH HORN (STI-1100 Series)

COVER

5.5 in.(140mm)

8.5 in.(216mm)

3.2 in.(81mm)

2 in.(51mm)

ALL MODELS END VIEW

COVER

3.2 in.(81mm)

2 in.(51mm)

5.5 in.(140mm)

5 in.(127mm)

3 in.(76mm)

SPACER

SPACER

SIDE VIEW

7.0 in.(178mm)

MODELS WITHOUT HORN (STI-1200 AND STI-3150 Series)

COVER

6.5 in.(165mm)

8.5 in.(216mm)

3.2 in.(81mm)

2 in.(51mm)

SPACER

3 in.(76mm)

DEPTH CHART FOR STI STOPPER II

4 in.(102mm)

5 in.(127mm)

5.5 in.(140mm)

STI-3100 SPACER

ADDS 2" DEPTH(51mm)

FOR SURFACE MOUNTED

PULL STATIONS

.75 in.(19mm)

1.625 in.(41mm)

2.375 in.(60mm)

2.75 in.(70mm)

3.2 in.(81mm)

5.5 in.(140mm)

HORN HOUSING

3 in.(76mm)

ALL MODELS END VIEW

4 in.(102mm)

5 in.(127mm)

5.5 in.(140mm)

STI-3100 SPACER

ADDS 2" DEPTH(51mm)

5.5 in.(140mm)

E

.75 in.

(19mm)

1.625 in.

(41mm)

2.375 in.

(60mm)

2.75 in.

(70mm)

3.2 in.

(81mm)

A

B

C

D

E

D

C

B

A

PUL

L D

OW

N

STI-1280 BACKPLATE

INSERT

(2) PROVIDED

STI-3003 GASKET (1/2 in. CONDUIT)
STI-3004 GASKET (3/4 in. CONDUIT
AND STI-3104 SPACER)

STI-3002 WEATHER GASKET

FOR WEATHER OPTION

(USE TWO WITH SPACER)

STI-3100 CONDUIT SPACER - STANDARD SPACER
INCLUDED WITH SURFACE MOUNT UNITS
STI-3104 CONDUIT SPACER ACCOMMODATES
3/4 in. CONDUIT FOR WEATHER STOPPER

SUB-315 GRILL

SUB-316
LOUVER

*NOTE: STI SUGGESTS USING THE

STI-1280 BACKPLATE FOR WEATHER UNITS

OR WHEN MOUNTED ON AN UNEVEN SURFACE.

WALL

OPTIONAL STI-1103

RELAY BOARD

RED +9, 12, OR 24 VOLTS

BLACK -9, 12, OR 24 VOLTS

GREEN NORMALLY OPEN

BLUE COMMON

WHITE NORMALLY CLOSED

3/32 in. ALLEN WRENCH
(NOT PROVIDED)

SWITCH LOCKING SCREW

5 INCHES OF CABLE IS
PROVIDED FOR SERVICE LOOP.
MAKE SURE THIS LOOP AND
ALL OTHER CABLES DO NOT
INTERFERE WITH STATION
OPERATION.

TO LOCK POWER SWITCH IN

THE "OFF" OR "ON" POSITION

TIGHTEN LOCKING SCREW FULLY

UNTIL SCREW MAKES CONTACT

WITH SWITCH PAD AS SHOWN.

OFF

OPTIONAL RELAY CONTACT SETTINGS

STI MODELS 1100RC, 1130RC, 1150RC AND 1155RC

( NOT USED WITH 9VDC BATTERY JUMPER)

*

*

*

ADDED
SILICONE

EXISTING

PULL STATION

SCREW WITHOUT SPACER

FLUSH MOUNT

WITH OPTIONS

SURFACE MOUNT

WITH OPTIONS

ANCHOR

(4) PROVIDED

EXISTING PULL

STATION

INSERT PLASTIC KNOCK-OUT (2) PROVIDED

INTO SPACER NOTCH IF CONDUIT IS NOT NEEDED

STI-3003 GASKET (USE WITH 1/2 in. CONDUIT)

STI-3004 GASKET (USE WITH 3/4 in. CONDUIT

AND STI-3104 SPACER)

STI-3100 CONDUIT SPACER SHOWN

WITH SUB-316 AND SUB-315

FOR ADDITIONAL VENTILATION

ORDER SUB-316 LOUVER KIT

OR SUB-315 GRILL

SCREW WITH SPACER

BACKPLATE
NOTE: WHEN DRILLING HOLE IN
BACKPLATE NEMA 3R INTEGRITY
IS COMPROMISED

ADHESIVE SIDE

STI-3002 WEATHER GASKETS

INSTALL THICK END OF GASKET

TOWARDS TOP OF ASSEMBLY

STI-1280

BACKPLATE

VIEW OF RELAY CONTACT

15 - 24 VDC

9 - 12 VDC

GROUND

NORMALL OPEN

NORMALLY CLOSED

COMMON

USE ONLY

9 VOLT BATTERY

JUMPER USED ON STANDARD 9

VOLT INTERNALLY

POWERED MODELS

JUMPER INSTALLED ON "RC" MODELS
FOR EXTERNALLY SUPPLIED 12VDC OR
24VDC POWER
NOTE: SMALL CONNECTOR ON JUMPER
FITS INTO PLUG ON RELAY BOARD

THIS JUMPER IS INCLUDED WITH "RC"
MODELS FOR USE WHEN INTERNAL
9VDC BATTERY POWER IS REQUIRED.
(BATTERY NOT INCLUDED)
SMALL CONNECTOR ON JUMPER FITS
INTO PLUG ON RELAY BOARD
USING THIS JUMPER REQUIRES
VOLTAGE SELECTOR SET TO 9V

STI-1103 RELAY
BOARD IS USED ON
"RC" MODELS

VOLTAGE SELECTOR

9V 24V

FACTORY VOLTAGE SETTINGS:
BATTERY POWERED UNITS: 9 VOLT
REMOTE POWER "RC" UNITS: 24 VOLT
USE 24 VOLT SETTING FOR USE WITH
12 VOLT DC INPUT POWER.

VOLUME SELECTOR

LOW

HI

FACTORY VOLUME SETTING: HIGH

USE ONLY

9 VOLT BATTERY

THIS JUMPER IS USED
ON STANDARD 9 VOLT
INTERNALLY POWERED
MODELS

THIS JUMPER IS THE STANDARD
INSTALLED JUMPER ON "RC" MODELS
FOR EXTERNALLY SUPPLIED 12VDC OR
24VDC POWER
NOTE: SMALL CONNECTOR ON JUMPER
FITS INTO PLUG ON RELAY BOARD

THIS JUMPER IS INCLUDED WITH "RC"
MODELS FOR USE WHEN INTERNAL
9VDC BATTERY POWER IS REQUIRED.
(BATTERY NOT INCLUDED)
NOTE: SMALL CONNECTOR ON JUMPER
FITS INTO PLUG ON RELAY BOARD
NOTE: USING THIS JUMPER REQUIRES
VOLTAGE SELECTOR SET TO 9V

STI-1103 RELAY
BOARD IS USED ON
"RC" MODELS

VOLTAGE SELECTOR

9V 24V

VOLTAGE SETTINGS:
STANDARD UNITS: 9 VOLT
"RC" UNITS: 24 VOLT
NOTE: USE 24 VOLT SETTING
FOR USE WITH 12 VOLT DC
INPUT POWER.

VOLUME SELECTOR

LOW

HI

STANDARD VOLUME SETTING: HIGH

FOR RETROFIT APPLICATIONS,

CUT GASKET AT THE BOTTOM TO

INSTALL BEHIND CONDUIT

FOR RETROFIT APPLICATIONS,

CUT GASKET AT THE BOTTOM TO

INSTALL BEHIND CONDUIT

EXPLODED

ELECTRONIC VIEW

Fig. 6

Gasket Installation

Use of gaskets is necessary to ensure a proper seal in weatherproof applications. Weather
Stopper models ship complete with all necessary gaskets and should be used accordingly.
For flush mount weather applications, one STI-3002 must be used between the cover and
wall or backplate (see Fig. 3). In surface mount applications, one STI-3002 must be placed
between the spacer and wall, while another STI-3002 must be placed between the spacer
and cover (see Fig. 4). An STI-3003 or STI-3004 gasket must be used around all entering
conduit. For surface mount applications, it is also recommended that the SUB-315 grill
be installed in the bottom knockout of the conduit spacer. This helps prevent excessive
condensation buildup. STI recommends gasket replacement every five years. (UL requires
listing of pull station to be UL Listed for outdoor installations.)

Battery Replacement Instructions

1. Remove the cover from the frame. It is not necessary to remove the cables from the

frame.

2. Use a 3/32” allen wrench to loosen the button head screw located next to the switch far

enough to slide the switch to the “off” position.

3. Holding the horn housing and cover in one hand, remove the button head screw located

on the top of the cover with the same allen wrench.

4. Set the clear cover aside and remove the horn housing cover.
5. Replace the battery with a 9 Volt battery only. Be careful to keep the wires away from the

slide switch and the micro-switch.

6. Reassemble the unit making sure that the horn housing fits into the tabs on the horn

housing cover; and that this assembly is mounted evenly into the clear cover.

7. Replace the button head screw through the top of the clear cover and into the top of the

horn.

8. Slide the switch to the “on” position. The horn should sound.
9. Push the switch in to silence horn while tightening the “on” position locking screw.
10. Replace the cover onto the frame and test by removing the cover from the frame. The

horn should sound when removed and silence when cover is replaced. If unit does not
operate correctly, contact Safety Technology International, Inc.

Advertising