AGA ELECTRIC RANGE EC LM-2 User Manual

Page 4

Advertising
background image

GENERAL NOTES

INSTALLATION

NOTE: THESE INSTALLATION INSTRUCTIONS SHOULD BE LEFT WITH THE APPLIANCE AND THE USER TO
RETAIN FOR FUTURE REFERENCE.

The Aga range is delivered unassembled. Before installation can be made, the site is inspected for suitability by an
authorised Aga distributor and corrected where necessary to conform with local installation codes or in the absence of local
codes with:

NATIONAL ELECTRICAL CODES ANSI/NFPA 70

Assembly is undertaken on site by the same Aga distributor to ensure correct performance and safety.

THE INSTALLATION OF THIS APPLIANCE MUST NOT BE LESS THAN 12mm FROM ANY SURFACE.

With specific exceptions, the installing of any type of Aga Range is subject to the respective directions contained in current
issue of the local Building Regulations. In addition, planning permission may need to be obtained, which should be applied
for separately.

The complete range is floor-mounted and the space in which the appliance is to be fitted must have the following minimum
dimensions:-

A minimum clearance of 60mm is required above the raised insulating cover handle.
Side clearance zero unless range is fitted against a wall, where 116mm is required at the right hand side for oven access.

In addition a minimum clearance of 1000mm must be available at the front of the cooker to enable the cooker to be
serviced.

To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above the
surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood
that projects horizontally, a minimum of 5” beyond the bottom of the cabinets.

NOTE: AGA RANGES ARE DELIVERED EX-WORKS UNASSEMBLED. ASSEMBLY IS UNDERTAKEN BY THE
AUTHORISED AGA DISTRIBUTOR/SPECIALIST.

Range Base or Hearth
It is essential that the base or hearth on which the range stands should be level and be capable of supporting the total
weight of the range.

Model EC-LM - 406 Kg

EE-LM - 584 Kg

The top of the hearth must be of non-combustible material for a minimum thickness of 12mm.
The wall behind the range must be of non-combustible material for a minimum thickness of 25mm.

Tiling
When the range is to stand in a recess, or against a wall which is to be tiled, in no circumstances should the tiles overlap
the cooker top plate.

Installation Requirements
The installation of the range must be in accordance with the relevant requirements of the local wiring and building
regulations.
It should be in accordance also with any relevant requirements of the local authority.

In your own interest, and that of safety to comply with the law, all appliances should be installed by an authorised Aga
distributor, in accordance with the relevant regulations.

4