Installation of alarm, Step 1 - mounting options, Installation of cabinet – STI 7525 User Manual

Page 4: Ount, Late or into, All without, Lectrical

Advertising
background image

STEP 1 - MOUNTING OPTIONS

4

INSTALLATION OF ALARM


O



DRILL

3-/16 DIA HOLES

19018 ANCHOR

#8-10

(2) PROVIDED

19039 SCREW
#6 x 1 1/4 in.
(2) PROVIDED

BASE PLATE

18074 SWITCH LOCK

SUB-SA505 KEY SWITCH
MOUNTING BRACKET

3 9/32 in.

18075 REPLACEMENT
#801 KEY

O

T

O

K

EY

M

OUNT

P

LATE OR INTO

W

ALL WITHOUT

E

LECTRICAL

B

OX

ENCLOSURE

ROUTE THE TWO KEY
SWITCH WIRES THROUGH
THE HOLE AS SHOWN

WIRE ACCESS HOLE

ROUTE THE TWO REED
SWITCH WIRES FROM
CABINET THROUGH THE
HOLE AS SHOWN

E

INSTALLATION OF CABINET

1. Insert the (4) 06298 mounting tabs fully into

back box mounting tab slots. Use rubber mallet
if necessary.

2. After selecting a suitable location, place cabi-

net in closed position, against the wall. Mark
and drill (4) 1/4 in. diameter holes. Insert the
(4) 19033 anchors. Mount cabinet by driving
in the four #10 x 1 1/2 in. screws.

Note: Installation of cabinet

should be before instal-
lation of alarm because
the mounting bracket
butts up to cabinet.