5

1 0 0 0 0 0 BUZZ
2 1 0 0 0 0 SLOW ON/OFF
3 0 1 0 0 0 SLOW SIREN
4 1 1 0 0 0 3 BEEP/PAUSE/REPEAT
5 0 0 1 0 0 UFO FAST
6 1 0 1 0 0 FAST SIREN
7 0 1 1 0 0 #5 FAST
8 1 1 1 0 0 #2 MEDIUM
9 0 0 0 1 0 #5 MEDIUM
10 1 0 0 1 0 SWOOP MEDIUM
11 0 1 0 1 0 #3 MEDIUM
12 1 1 0 1 0 BUZZ TONE
13 0 0 1 1 0 STEADY FAST
14 1 0 1 1 0 SWOOP SLOW
15 0 1 1 1 0 CONTINUOUS
16 1 1 1 1 0 FAST REPEAT

17 0 0 0 01 STANDARD ALARM
18 1 0 0 0 1 #3 FAST
19 0 1 0 0 1 #5 SLOW
20 1 1 0 0 1 FAST BEEP
21 0 0 1 0 1 SOUND A
22 1 0 1 0 1 SOUND B
23 0 1 1 0 1 SOUND C
24 1 1 1 0 1 SOUND D
25 0 0 0 1 1 SOUND D LOUD
26 1 0 0 1 1 SOUND E
27 0 1 0 1 1 SOUND F
28 1 1 0 1 1 SOUND G
29 0 0 1 1 1 SOUND H
30 1 0 1 1 1 #4 LOW
31 0 1 1 1 1 SOUND K
32 1 1 1 1 1 CONTINUOUS FAST

1

ALARM TIMING

VOLUME

STROBE TIMING

ON

OFF

1

2

3

4

5

0

15 seconds 1 1 1 1 High
30 seconds 1 0 1 0 1
60 seconds 0 1 0 1 Low
Continuous 0 0 0 0 0

1 = ON

0 = OFF

STEP 3 - ALARM TONES - S1

STEP 4 - ALARM TIMING AND VOLUME - S2


S1

ALARM TONE

S2

ALARM TIMING

STROBE TIMING

VOLUME

LED QTY 10

LOW BATTERY

INDICATOR LED

TERMINAL STRIP

TAMPER SWITCH

(REAR VIEW)

WIRE ENTRY

BATTERY

BATTERY CABLE

SIREN

O



O

1 2 3 4 5

1 2 3 4 5

ALARM

TIMING

1 2

3 4

5

VOLUME

STROBE

SIREN

*

Factory default settings

*

*

STEP 2 - ELECTRONIC SETUP - SELECT ALARM TONE

AND TIMING SEQUENCE

NOTE: Select-Alert must be on a flat surface and lens must be

installed or the tamper switch will trigger the alarm.

NOTE: Sound may be disabled by clipping

wires to the siren. THIS WILL VOID ALL
WARRANTIES. Remove two screws on cir-
cuit board; leave enough length of wire
to possibly reattach in the future. Then
insulate wires to prevent shorting to
electronic components.


O




O

WIRES TO SIREN

Advertising