Switch settings, Circuit board set-up, Alarm circuit board set-up – STI 7523 User Manual

Page 2: Safety technology international, inc, Safety technology international (europe) ltd, Sti-usa

Advertising
background image

SWITCH SETTINGS

Volume - High (105 dB) at 1 ft.

ON*

Volume - Low (95 dB) at 1 ft.

OFF

Duration - 30 Second Alarm

OFF

OFF

Duration - 180 Second Alarm

OFF

ON

Duration - Continuous Alarm

ON*

OFF*

Duration - Annunciator Mode

ON

ON

Trip - Immediate

OFF*

Trip - 15 Second Delay

ON

Arming - Immediate

ON*

Arming - 15 Second Delay

OFF

FEATURE

JP2

JP3

JP4

JP5

JP7

*Factory Settings
Note: Slide black lever to desired ON/OFF position as labeled on circuit board.

Printed in USA

Safety Technology International, Inc.

2306 Airport Road • Waterford, Michigan 48327-1209
Phone: 248-673-9898 • Toll Free: 800-888-4784
Fax: 248-673-1246 •

www.

sti-usa

.com

Safety Technology International (Europe) Ltd.

Unit 49G Pipers Road • Park Farm Industrial Estate • Redditch
Worcestershire • B98 0HU • England • Tel: 44 (0) 1527 520 999
Fax: 44 (0) 1527 501 999 • Freephone: 0800 085 1678 (UK only)
E-mail: [email protected] • Web: www.sti-europe.com

CIRCUIT BOARD SET-UP

N

Mark and drill 3/16 in.

Nex

JP5

JP2

JP4

JP3

JP7

ALARM VOLUME SWITCH

TRIP DELAY SWITCH

ARMING SWITCH

(FACTORY DEFAULT SETTINGS)

(ON)

(ON)

(OFF)

(OFF)

(OFF)

ALARM CIRCUIT BOARD SET-UP

ALARM

DURATION

SWITCH

TERMINAL BLOCK

D







Inst. Sht. 7523, JAN2010

B

FROM MAGNETIC
CONTACT SWITCH

N

TERMINAL STRIP

NC COM NO GD

V+

RS1

RS2

KEYSW

VIEW B

FO

R

M

C

D

R

Y

CO

N

TA

CT

S

R

EM

O

TE

P

O

W

ER

IN

P

U

T

9

-2

4

V

D

C

K

EY

S

W

IT

CH

TE

R

M

IN

A

LS

TERMINAL BLOCK WIRING CONNECTIONS

M

A

G

N

ET

IC

C

O

N

TA

CT

R

EE

D

S

W

IT

CH

JU

M

P

ER

M

Electronic warranty form at www.sti-usa.com/wc14