ZONE PROGRAMMING PROCEDURES

Only receives wireless signals from the STI Wireless Alert Series products. Program up to 4
sensors or keyfobs. Does not allow programming into an occupied zone. Cannot program
the same sensor into more than one zone. The unit will state, “Please change to normal
mode if programming is completed.” (Repeats every 60 seconds.) Default language is English.
Move dip switch 1 to the “on” (up) position for Spanish.

MODES OF OPERATION

Set at time of programming by zone

Zone Latching: Dip Switch #2 ‘OFF’

When sensor is triggered, red zone light is solid. “Latching” let’s you know a zone was triggered,
but the alert has cleared (flashing red LED). To reset, push the acknowledge button.

Zone Auto Restore: Dip Switch #2 ‘ON’

“Auto-Restore” sounds when a zone has been triggered. Zone automatically restores to solid
green light without pressing acknowledge button.

Dip Switch Functions

DIP

NORMAL MODE

PROGRAM MODE

SWITCH

OFF (DOWN)

ON (UP)

OFF (DOWN)

ON (UP)

1

ENGLISH*

SPANISH

2

LATCHING*

AUTO RESTORE

3 PRE-ALERT TONE*

NO TONE

TONE/WORD SELECT

4

TONE/WORD SELECT

5

TONE/WORD SELECT

6

TONE/WORD SELECT

7

TONE/WORD SELECT

8

TONE/WORD SELECT

*Default Mode