RELAY MODE
N.O. - Relay switches with power to circuit - Fail Safe
N.C. - Relay is in same state as with no power to circuit - Fail Secure

TO CHANGE TIMER SETTINGS
Cut jumpers with “X”, do not cut jumpers with “

“.

Default timer setting is 15 seconds.

If the trigger is activated during a timing cycle, the timer is restarted.

NOTE: To ensure jumpers do not reattach or short to other components, cut
jumper off completely flush to PCB.

Electronic warranty form at www.sti-usa.com/wc14.

+

-

x

x

x

x

TIMER START

SWITCH

TIMER OVERRIDE

RESET (OPTIONAL)

*POWER IN

12-24 VAC/VDC,15mA

TO MAGNETIC LOCK

(FAIL SAFE MODE)

JUMPERS

15 SEC

RELAY MODE JUMPER

30 SEC

45 SEC LATCH









IF TRACES ARE INADVERTENTLY CUT,

SOLDER JUMPER WIRES USING

APPROPRIATE HOLES.

RELAY MODE

N.O.

N.C.

NO CUT
CUT

15s
30s
45s
Ltch

Relay

NO

Relay

COM

Relay

NC

Trig

Input

Com

Reset

Power

Input

+

-

12 to 24 Volts

AC or DC

MODEL LT-1

RELAY MODE

N.O.
N.C.

NO CUT
CUT

15s
30s
45s
Ltch