Heat/blower equipment, Cooling equipment – Aprilaire 8344 User Manual

Page 8

Advertising
background image

7

FAN

RELAY

2ND

STAGE

HEAT

1ST

STAGE

HEAT

R

HEAT/BLOWER EQUIPMENT

C

G

Y1

W1

Y2

W2

1ST STAGE

COOL

2ND STAGE

COOL

L1

L2

120

VAC

24

VAC

1ST

STG

COOL

2ND

STG

COOL

COOLING EQUIPMENT

Y1

C

Y2

APRILAIRE MODEL 8348

OR 8366 THERMOSTAT

LO

HI

W

RC

RH

W2

Y

Y2

G

HI opens at 100

°F±9°F

LO closes at 41

°F±9°F

GAS

ELEC

AUTO

ON

Diagram 2 – Model 8348 or 8366 Thermostat Wiring