Displaying sflow information – Brocade FastIron Ethernet Switch Administration Guide User Manual

Page 256

Advertising
background image

Enabling the sFlow agent to export CPU-directed data

To enable the sFlow agent on a Brocade device to export data destined to the CPU to the sFlow
collector, enter the following command.

device(config)# sflow export cpu-traffic

Syntax: [no] sflow export cpu-traffic

By default, this feature is disabled. The sFlow agent does not send data destined to the CPU to the
sFlow collector.

Specifying the sampling rate for exported CPU-directed data

The sampling rate is the average ratio of the number of packets incoming on an sFlow-enabled port, to
the number of flow samples taken from those packets. You can optionally set the sampling rate for
CPU-directed data exported to the sFlow collector. For example, to set this sampling rate to 2048,
enter the following command.

device(config)# sflow export cpu-traffic 2048

Syntax: [no] sflow export cpu-traffic

The default sampling rate depends on the Brocade device being configured. Refer to

Changing the

sampling rate

on page 249 for the default sampling rate for each kind of Brocade device.

Displaying sFlow information

To display sFlow configuration information and statistics, enter the following command at any level of
the CLI.

device#show sflow

sFlow version:5

sFlow services are enabled.

sFlow agent IP address: 10.123.123.1

4 collector destinations configured:

Collector IP 192.168.4.204, UDP 6343

Collector IP 192.168.4.200, UDP 6333

Collector IP 192.168.4.202, UDP 6355

Collector IP 192.168.4.203, UDP 6565

Configured UDP source port: 33333

Polling interval is 0 seconds.

Configured default sampling rate: 1 per 512 packets

Actual default sampling rate: 1 per 512 packets

The maximum sFlow sample size:512

exporting cpu-traffic is enabled

exporting cpu-traffic sample rate:16

exporting system-info is enabled

exporting system-info polling interval:20 seconds

10552 UDP packets exported

24127 sFlow samples collected.

sFlow ports: ethe 1/2 to 1/12 ethe 1/15 ethe 1/25 to 1/26 ethe 4/1 ethe 5/10 to

5/20 ethe 8/1 ethe 8/4

Module Sampling Rates

---------------------

Slot 1 configured rate=512, actual rate=512

Slot 3 configured rate=0, actual rate=0

Slot 4 configured rate=10000, actual rate=32768

Slot 5 configured rate=512, actual rate=512

Slot 7 configured rate=0, actual rate=0

Slot 8 configured rate=512, actual rate=512

Port Sampling Rates

-------------------

Port 8/4, configured rate=512, actual rate=512, Subsampling factor=1

Port 8/1, configured rate=512, actual rate=512, Subsampling factor=1

Port 5/20, configured rate=3000, actual rate=8192, Subsampling factor=16