Brocade FICON Administrator’s Guide (Supporting Fabric OS v7.3.0) User Manual

Page 27

Advertising
background image

NOTE
Zoning does not replace the need to set up the connectivity from the host to storage control units in the
HCD or Input/Output Configuration Program (IOCP). For more information on zoning, refer to the Fabric
OS Administrator's Guide
.

FIGURE 13 Complex cascaded zoning

Zone A (Blue): Any CHPID connected to Director 1, except CHPID 79, can get to any control unit
connected to Director 1. The zone includes all ports in Director 1 except ports 4, 5, and 6.

Zone B (Orange): Any CHPID connected to Director 2, except CHPID 7A, can get to any control unit
connected to Director 2. The zone includes all ports in Director 2 except ports 4, 5, and 6.

Zone C (Green): Any CHPID connected to Director 11 can get to any control unit connected to Director
11. The zone includes all ports in Director 11 except ports 5 and 6. Adding ports 5 and 6 to the zone, so
that all ports in the switch or Backbone are in the same zone, would not affect permitted connectivity
and may be a more practical alternative.

Zone D (Yellow): Any CHPID connected to Director 12 can get to any control unit connected to Director
12. The zone includes all ports in Director 12 except ports 5 and 6, which are used for ISLs.

Red Zone E: CHPID 79 can talk only to the remote tape connected to ports 7 and 8 on Director 11. The
zone includes port 4 of Director 1 and ports 7 and 8 of Director 11. Either ISL can be used.

Purple Zone F: CHPID 7A can talk only to the remote tape connected to ports 7 and 8 on Director 12.
The zone includes port 4 of Director 2 and ports 7 and 8 of Director 12. Either ISL can be used.

Introducing FICON