Brocade SAN Analytics Management Pack for VMware vCenter Operations Management Suite User’s Guide V1.0 User Manual

Page 18

Advertising
background image

10

Brocade SAN Analytics Management Pack for VMware vCenter Operations Management Suite User Manual

53-1003192-01

FC Port resources

2

FEC Uncorrected Blocks — Indicates the FEC Uncorrected Blocks Count.

Invalid Ordered Sets — The total number of invalid ordered sets received at the port.

Invalid Transmissions — The number of transmission words that had an invalid character
(8b10b code violation) in one or more of its characters, had a K28.5 (8b10b control) in its
second, third, or fourth character position, or had an incorrect Beginning Running Disparity.
This count is part of the Link Error Status Block (LESB).

Rx Link Resets — The total number of Link resets. This count is the number of link resets
received.

Sequence Errors — The total number of primitive sequence protocol errors that detected at this
port. This count is part of the Link Error Status Block (LESB).

Signal Losses — The number of times the signal is lost on the Port since the last device reset.
This count is part of the Link Error Status Block (LESB).

Sync Losses — The number of times that synchronization is lost on the Port since the last
device reset. Synchronization is assumed lost which a timeout period (identified by the
Receiver Transmitter Timeout property) is exceeded. This count is part of the Link Error Status
Block (LESB).

Truncated Frames — The total number of frames received at this port where the frame length
was less than the minimum indicated by the frame header.

Tx Link Resets — The total number of Link resets. This count is the number of link resets
transmitted.

Advertising