Brocade SAN Analytics Management Pack for VMware vCenter Operations Management Suite User Manual

53-1003192-01

Event handling configuration

3

15. Select the MIB Alias check box to display trap aliases.

16. Select BD-MD and SW-MB from the Available Trap Type list and click the right arrow button to

move them to the Selected Trap Type list.

17. Click OK on the Add Trap Filter dialog box.

SNMP Traps and Syslog messages from the selected switches or fabric will now be forwarded
to the configured destination server.

18. Click OK on the SNMP Trap Forwarding dialog box.

Configuring devices for event handling

1. Login to the device.

2. Use the snmptraps --send -trap_name bd-trap to send bottleneck traps.

To remove an old bottleneck event from the interface, use the snmptraps --send -trap_name
bd-clear-trap to clear bottleneck traps.

3. Use the snmpconfig –show snmpv1 command to make sure that the v1 traps are forwarded to

Brocade Network Advisor.

If the Brocade Network Advisor server does not display in the list, use the snmpconfig –set
snmpv1 command to add it.

4. Use the snmpconfig –show snmpv3 to make sure that the v3 traps are forwarded to Brocade

Network Advisor.

If the Brocade Network Advisor server does not display in the list, use the snmpconfig –set
snmpv3 command to add it.

Verifying alerts

When you complete configuration of vCenter Operations Manager, Brocade Network Advisor, and
any devices for event handling, generate events in Brocade Network Advisor to verify the alerts in