Tm xpp link status check, Examples – Brocade MLX Series and NetIron Family (Supporting Multi-Service IronWare R05.6.xx) User Manual

Page 41

Advertising
background image

Brocade MLX Series and NetIron Family Documentation Updates

33

53-1003301-07

TM XPP link status check

1

TM XPP link status check

The link between TM and XPP is periodically monitored to determine link issues at run time and
perform appropriate recovery.

Brocade(config)#sysmon tm nif-check threshold

count

120

Brocade(config)#sysmon tm nif-check disable-ports

Syntax: [no] sysmon tm nif-check threshold count polling period

Syntax: [no] sysmon tm nif-check action

disable-ports ports disable for nif errors

reset-linecard linecard reset for nif errors

Examples

Default action:

Syslog:Mar 4 20:33:57:A:System: LP15/TM0: All ports down due to TM XPP link

down

Mar 4 20:33:57:I:System: Interface ethernet 15/4, state down - TM XPP link

down

Mar 4 20:33:57:I:System: Interface ethernet 15/3, state down - TM XPP link

down

Mar 4 20:33:57:I:System: Interface ethernet 15/2, state down - TM XPP link

down

Mar 4 20:33:57:I:System: Interface ethernet 15/1, state down - TM XPP link

down

Snmp trap:

Health Monitoring: LP15: All ports down due to TM XPP link down

Line card reset action:

Syslog:

Mar 4 20:33:57: D:System: Module reset in slot 1, triggered by TM Health

Monitoring

Mar 4 20:33:57: D:System: TM Health Monitoring detects an issue in slot 1 ppcr 1

TM XPP link down

Snmp trap:

Type- debugging

System: Module reset in slot 1, triggered by TM Health Monitoring

Advertising