Congratulations, you heve just purchased a quality Brass Gear Pump, designed to give you years of trou-
ble free operation when operated from a power source, witin the design of the pump. (See recommended
operating RPM’s and horsepowers
).

SAFETY INSTRUCTIONS:

This fine pump that you have just purchased is designed from the latest in material and
workmanship.
Before installation and operation, we recommend the following procedures:

CHECK WITH YOUR LOCAL ELECTRICAL AND PLUMBING CODES TO ENSURE
YOU COMPLY WITH THE REGULATIONS. THESE CODES HAVE BEEN
DESIGNED WITH YOUR SAFETY IN MIND. BE SURE YOU COMPLY WITH THEM.

WE RECOMMEND THAT A SEPARATE CIRCUIT BE LEAD FROM THE HOME
ELECTRICAL DISTRIBUTION PANEL PROPERLY PROTECTED WITH A FUSE OR
A CIRCUIT BREAKER. WE ALSO RECOMMEND THAT A GROUND FAULT
CIRCUIT BE USED. CONSULT A LICENSED ELECTRICIAN FOR ALL WIRING.

THE GROUND TERMINAL ON THE THREE PRONG PLUGS SHOULD NEVER BE
REMOVED. THEY ARE SUPPLIED AND DESIGNED FOR YOUR PROTECTION.

NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR
PRODUCT WITH THE POWER CONNECTED. DO NOT ONLY UNSCREW THE
FUSE OR TRIP THE BREAKER, REMOVE THE POWER PLUG FROM
THE RECEPTACLE.

A

B

C

D

APPLICATION

This GEAR PUMP is designed to operate in either a clokcwise or counter clockwise rotation from
its power source. Looking at the pump from front, (see picture #1) the inlet (suction) will be
located on the right side of the pump body. For counter clockwise rotation
the inlet and outlet will be reversed.

When the pump is properly installed, it will lift water 20-22 feet, unprimed.
As the pump gears wear with time, its ability to lift water gradually be
reduced. A FOOT VALVE is recommended on the end of the SUCTION
LINE to maintain prime at the pump level.

CONSTRUCTION FEATURES AND CAUTIONS

BURKE Gear Pumps are equipped with self lubricating bearings. These bearings are replaceable
should wear be caused by pumpimg abrasives. These bearings require no lubrification other than
from the liquid being pumped caution : Do not pump dry for longer than normally required to prime
the pump. do not restrict the pump on its suction side. use 1/2” or larger suction line for model
700720. Use a 314” or larger suction line for model 700721. avoid all unnecessary kinks, bends,
elbows in the suction line. Make sure all connections on suction line do not leak.

These Gear Pumps are designed to operate up to 1800 RPM when pumping water or equally thin
liquids. When pumping heabier liquids, pump speed should be reduced. maximum liquid
temperature 130

0

F.

PICTURE # 1