Replacing the stylus, Replacing the cartridge – Audio-Technica AT-LP120-USB User Manual

Page 8

Advertising
background image

8

Replacing the Stylus

Replacing the Stylus
The AT-LP120-USB comes supplied with a high-quality Audio-Technica

ATP-2 cartridge. The stylus should be replaced with a genuine

Audio-Technica ATP-n2 stylus.

1. Release the headshell assembly from the tone arm by turning the

locking ring clockwise.

2. Carefully remove the headshell assembly and turn it over so the

stylus is visible.

3. Remove the stylus assembly by pulling it away from the cartridge

body at a slight angle. [See Figure 7.]

4. Remove the replacement stylus from its package and carefully

align it with the cartridge body.

5. Gently push the stylus onto the cartridge body, being careful not to

damage the stylus. The stylus assembly should click into place.

6. Replace the headshell assembly on the tone arm and secure with

the locking ring.

Figure 7 – Removing the Stylus

Mechanical Assembly
1. To replace the cartridge, first release the headshell assembly from

the tone arm by turning the locking ring clockwise. Carefully

remove the headshell assembly and turn it over so that the stylus

is visible. Remove the stylus assembly by pulling it away from the

cartridge body at a slight angle. [See Figure 7.] Place the stylus

assembly out of harm’s way.

2. Remove the cartridge body by loosening the two small screws

securing the cartridge to the headshell. Set the hardware aside to

be reused with the new cartridge.

3. Unpack the new cartridge and carefully remove its stylus

assembly. Place the stylus assembly out of harm’s way. Mount

the new cartridge to the headshell assembly. Use the mounting

hardware supplied with the new cartridge or the existing hardware

removed at step 2. Tighten the mounting screws until just snug.

Replace the stylus assembly briefly to check for mechanical

interference with the mounting hardware. The stylus assembly

should click into place. Make certain the new cartridge is properly

positioned in the headcase assembly per the manufacturer’s

instructions. Again remove the stylus assembly for safekeeping.

Electrical Connections
1. Four terminals at the rear of the cartridge are color coded to match

standard wiring in stereo tone arms. [See Figure 8.] Connect the

cartridge with the slip-on lugs provided on the headshell wiring.

neVeR SOLDeR TO CARTRIDGe TeRMInALS! Heat applied to

the terminals will damage the internal cartridge wiring.

2. For monaural operation, the left and right signal leads should be

connected to the monaural output terminal and the left and right

ground leads should be connected to the ground terminal.

3. Finally, gently push the stylus onto the cartridge body being

careful not to damage the stylus. The stylus assembly should click

into place. Replace the headshell assembly onto the tone arm

taking care not to damage the stylus assembly.

(note: After replacing the cartridge, reset the tone arm balance, stylus

force and anti-skate based on the new cartridge’s specifications.)

Figure 8 – Electrical Connections

Left Output

(White)

Right Output

(Red)

Right Ground

(Green)

Left Ground

(Blue)

Replacing the Cartridge

Advertising