background image

4801-5146 Rev 2-08

Motor Controls

Page 2

1.

Ratings and Specifications

Check Motor Control Ratings Label on front of the controller for specific ratings.

The following motor controls are designed for specific motors. Use the make and model number
off the motor to insure that the proper controller is used for each motor. Each controller will have
an identification label located on the front of controller that will have the model number of the
controller and the specific ratings for that controller.

Controller 6607-7504 – Contains 5 Amp fuse
For use with:

o

Marathon Motor Model 7PM56C17F5959 1/3 hp. 240V Single Phase

(See Section 7.3 for wiring)

Controller 6607-7505 – Contains 15 Amp fuse (3010-2994)
For use with:

o

MagneTek Motor Model C337 1/3 hp. 240V Single Phase

(See Section 7.4 for wiring)

o

A. O. Smith Model 193443 (See Section 7.4)

o

Lock Motor 3017-5411 (See Section 7.5)

Controller 6607-7506, 220V 3Phase 1HP– Contains 3.7 -5.5 Amp Thermal Overload
(3015-2892)
For use with:

o

Any 1 hp. Three Phase motor at 220VAC

(See Sections 7.2 & 7.6 for wiring)

Controller 6607-7507, 480V 3Phase 1HP – Contains 2.6 -3.7 Amp Thermal Overload
(3015-2895)
For use with:

o

Any 1 hp. Three Phase motor at 480VAC

(See Sections 7.2 & 7.6 for wiring)


2. Warnings

Warning!

When This Controller Is Used In A Life Support Heating And Ventilation System

Where Failure Could Result In Loss Or Injury, The User Should Provide Adequate

Back Up, Or Accept The Risk Of Such Loss Or Injury!

Advertising