Hired-Hand Circulation and Stir Fans: MEGA FLOW Motor Replacement 36 (91 cm) Fan Housing User Manual

Warning, 36″ (91 cm) dairy fan housing, Before installing motor

Advertising
background image

HIRED-HAND MFG., INC.

• 1733 County Road 68 • Bremen, Alabama 35033 • Phone 256-287-1000 • Fax 256-287-2000

Manual Part No. 4801-5159

Page 1 of 2

Use a 12

point 3/8"

Socket


















MOTOR REPLACEMENT INSTRUCTIONS

1. Disconnect all Electrical power to the Fan.

2. Remove the fan from its installation position and

place the fan on a level surface. Remove both the
front and rear Wire Guards. Save the hardware for
re-installation later.


3. Remove the power cable from the motor housing.

4. Position the fan with the blades facing upward.

5. Using a 12 point 3/8 socket, remove the fan blade.

See Figure 1.










1. Disconnect power source before installing or

servicing fan. Failure to disconnect power
source can result in property damage, serious
injury, or death.

2. When this fan is used in a life support ventilation

system where failure could result in loss or
injury, the user should provide adequate backup
ventilation, or accept the risk of such loss or
injury.

WARNING

!

M E G A F L O W

®

M o t o r R e p l a c e m e n t

36″ (91 cm) Dairy Fan Housing

1. Inspect motor for damage in transit. Check for

loose, missing, or damaged parts.

2. Do not operate fan until you are completely

familiar with its operation. READ ALL
INSTRUCTIONS PRIOR TO INSTALLATION.

Before Installing Motor

Post Mount

36" MegaFlow Fan using Ceiling Mount

Option

36" MegaFlow Fan with Post Mount

Option

Figure 1 – Remove the Fan

NOTE: Rear Guard removed

Crescent wrench

12 point 3/8" socket

3/8" Ratchet

2 1/4" Hole saw

7/16” Socket

9/32” Socket

9/32” Drill bit

Cordless drill

Tools Required

Description

Part No.

Motor

3017-3100

Replacement parts