HIRED-HAND MFG., INC.

• 1733 Co Rd 68 • Bremen, Alabama 35033 • Phone 256-287-1000 • Fax 265-287-2000

Manual Part Number 4802-5095 Rev. 12-04 Page 2 of 2

4. Attach the Belt Tensioner as shown in Figure 2 using 6 cap screws, 2 flat washers, and 6 lock nuts as

specified in the parts list above. Note the location of the two flat washers for the mounting of the Tensioner.


5. Refer to Figure 3. Re-Install the motor in the upper mounting position using the four cap screws and lock

nuts removed in Step 3.




















6. Refer to Figure 4.

Use a straight edge to
align the prop pulley
and the motor pulley
with the tensioner
pulley as shown. If
necessary, loosen the
prop pulley set screw.
Securely tighten set
screw of motor pulley
and prop pulley.
Recommended torque
is 110 in. lbs.
minimum.


7. Install belt onto motor

pulley, tension pulley
and prop pulley.


8. Re-assemble the fan

and test for proper operation.


9. Installation complete.