HIRED-HAND MFG., INC.

• 1733 County Road 68 • Bremen, Alabama 35033 • Phone 256-287-1000 • Fax 256-287-2000

Manual Part No. 4801-5180 Rev 2-09 Page

2

of

2

Pilot hole

at top

outside of

cone

Mounting Brackets

Top and Bottom bolts are
inserted from inside the
cone.





4. To complete the last flange

connection, roll the cone panels
so the small end is on the floor.
See Figure 2. IMPORTANT!
The four pilot holes should be at
the top end on the outside of the
cone.






5. Install the cone Mounting

Brackets to the fan housing
using two 5/16”-18x5/8” carriage
bolts in each mounting bracket.

6. Mount cone to fan. Bend the

mounting brackets back slightly
to help clear the area of the
cone edges. Hang the centered
slot in the small end of the cone
over the Pim screw mounted on
the Fan housing. See Figure 3.
Screw can be fastened with
¼”x20 lock nut, if necessary (not
included).

7. Align the cone over the

remainder of the fan housing.
Using four 1/4”-20x3/4” Truss
Head Phillips bolts and 1/4-20
lock nuts, insert the bolts from
the inside of the cone. See
Figure 4.



















Cone attaches over
the top Pim screw

Figure 3: Install Cone Mounting Brackets

Figure 2: Assembled Cone

Figure 4: Mount Cone onto Fan