Mega flow, Fan & cone installation – Hired-Hand Mega Flow SlantWall Fans: 36 48 & 52 Mega Flow Cone Fan Unassembled User Manual

Page 7

Advertising
background image

Part No. 4801-3006 Rev 6/07

36" 48" & 52" Mega Flow - Unassembled

Page 7 of 12

MEGA FLOW

Fan & Cone Installation

SLANTWALL

Rear Gusset

Flat Washer
(1003-1461)






















10. Refer to Figure 2. Install the two

tension latches (1040-0105) to the
right and left cabinet panels with
3/16" fan rivets (1005-5006).


11. Refer to Detail F. Install the

right, left, bottom and top
cabinet panels to the fan orifice
using fan rivets (1005-3049).


12. Refer to Detail F. Install four 1/4"-

20 x 1" screws (1004-2533), flat
washers (1003-1461), and lock nuts
(1001-1446) to the rear gusset
through the top and side of the
cabinet.



























Figure 2 - Assemble Cabinet, Fan and Motor

Cabinet Bottom

36" (0404-6973)
48" (0404-6971)
52" (0404-6937)

Cabinet Top

36" (0404-6974)
48" (0404-6978)
52" (0404-6938)

Cabinet Right

36" (0404-6976)
48" (0404-6980)
52" (0404-6939)

Cabinet Left

36" (0404-6975)
48" (0404-6979)
52" (0404-6940)

Fan Prop

Key Shear

(1019-2417)

Latch

(1040-0105)

Gusset

¼" - 20 x 1"

(1004-2533)

Detail F

Lock Nut

(1001-1446)

Use rear set of

mounting holes