Hired-Hand Super-Savers (Forced Air Heaters) XL: Blower Motor Insulation Installation User Manual

Blower motor insulation installation, Super saver xl heaters

Advertising
background image

Blower Motor Insulation Installation

Super Saver XL Heaters

Part No. 4801-2980

Tools Required

5/16 inch Wrench

1/4 inch Nut-driver

1/8 inch Allen Wrench

Directions

Study the drawing below before proceeding.

Blower Housing

Setscrew

Blower Wheel

Motor Mounting Plate

Motor

Insulation

Figure 1

Figure 1 above shows the components in the blower motor assembly. Make sure that each component
goes on the shaft in the order shown.

1. Disconnect electrical power to the heater and shut off gas supply.

2. Open the Side-Swinging door and find the motor.

3. Disconnect the wires to the motor.

4. Make match marks on the motor mounting plate and the blower housing. This is to make sure the

assembly can be replaced in the same alignment as it is currently installed.

5. Remove the blower motor assembly by removing the (ten) 1/4 inch screws from the motor mounting

plate. (Note: For easier removal of blower assembly, leave one screw on the top row for last.)

6. Remove blower wheel using the 1/8 inch allen wrench.

Advertising