23

Measurement Errors
Error messages will appear if the unit’s receiver is not getting a
sufficient laser return signal.
Common surfaces that could cause an error reading:

- Water or other fluids
- Translucent to clear surfaces like glass or acrylic
- Porous or dark surfaces may require longer reading times or

cause an error reading

- Moving surfaces or objects such as curtains
- Highly reflective or angled surfaces may deflect the laser

beam signal

Error Codes
Code Description

Solution

Err01 Distance is outside of measuring range

Measure in a shorter
distance or longer distance

Err02 Reflected signal is too weak

Measure a better surface

Err03 Out of display range

Maximum Value: 99,999
Split up measurement area
into smaller segments.

Err04 Pythagorean theorem calculation error

Check and verify value or the
sequence of measurements
is correct

Err05 Low Battery

Install a new battery

Err06 Temperature is outside of working range

Measure in an environment
within specified working
temperature range

Err07 Ambient light is too strong

Measure in a darker place
(shadow target)

6834H-English_Manuals 4/2/13 1:28 PM Page 23