Installation, Physical dimensions, Rated output – Lincoln Electric IM467 SQUARE WAVE TIG 355 User Manual

Page 9: Output, Recommended input wire and fuse sizes

Advertising
background image

INSTALLATION

A-1

A-1

SQUARE WAVE TIG 355

TECHNICAL SPECIFICATIONS - SQUARE WAVE TIG 355

INPUT - SINGLE PHASE ONLY

Input Voltages:

208

230

460

575

Input Currents

@ 350A/34 VDC

110

100

50

40

RATED OUTPUT

Duty Cycle

Amps

Volts at Rated Amperes

40% Duty Cycle

350

34 v

60% Duty Cycle

300

32 v

100% Duty Cycle

220

29 v

OUTPUT

Maximum Open

Continuous

Circuit Voltage

Current Range

Auxiliary Power

80 Volts Max.

2-400 Amps AC and DC

115 VAC

15 Amps Continuous

RECOMMENDED INPUT WIRE AND FUSE SIZES

Type 75°C

Type 75°C

Fuse

Input

Type75°C

Copper Ground

Type 75°C

Copper Ground

Fuse

Input

(Super Lag)

Ampere

Copper Wire in Wire in Conduit

Copper Wire in

Wire in Conduit

(Super LAG)

Voltage /

or Breaker Rating on

Conduit AWG

AWG (IEC)

Input

Conduit AWG

AWG (IEC)

or Breaker

Frequency

Size

Nameplate

(IEC) Sizes

Sizes

Amperes

(IEC) Sizes

Sizes

Size

208/60

150

110

4 (25mm

2

)

6 (16mm

2

)

148

2 (35mm

2

)

6 (16mm

2

)

200

230/60

125

100

6 (16mm

2

)

6 (16mm

2

)

134

2 (35mm

2

)

6 (16mm

2

)

175

460/60

60

50

8 (10mm

2

)

10 (6mm

2

)

67

6 (16mm

2

)

8 (10mm

2

)

80

575/60

50

40

8 (10mm

2

)

10 (6mm

2

)

54

6 (16mm

2

)

8 (10mm

2

)

70

PHYSICAL DIMENSIONS

Height

Width

Depth

Weight

884 mm

565 mm

660 mm

232 kg

34.84 in.

22.25 in.

26.00 in.

510 lbs.

OPERATING TEMPERATURE RANGE STORAGE TEMPERATURE RANGE

0° to 40°C

-50° to 85°C

For all Stick, DC TIG, and Balanced AC TIG

Welding at 350A/34V/40% Duty Cycle Based

on the 1990 U.S. National Electrical Code

For Unbalanced AC TIG Welding Above 230 Amps,

300/32V/60% Duty Cycle, Unbalance Based on the

1990 U.S. National Electrical Code

Advertising