Recommended Processes and Equipment

Recommended Processes

SAW (alternating current [AC], DC+ and DC-) up to 1,000 amps

Tiny Twin.

Process Limitations

The Cruiser™ tractor does not support open arc procedures.

The Cruiser™ tractor only supports one arc.

Equipment Limitations

Because of cable inductance, do not use more than 100 feet (30 m) of electrode and

100 feet (30 m) of work cable.

For robust digital communications, do not use more than 200 feet (60 m) of control

cable.

The Cruiser™ tractor operates on 40 volts direct current (VDC) only.

There is no 115 volts alternating current (VAC) in the Cruiser™ tractor.

The flux hopper holds a maximum of 15 lbs (6.8 kg) of flux.

Recommended Power Sources

Power Wave AC/DC 1000.