TROUBLESHOOTING & REPAIR

E-3

INVERTEC V250-S

Observe all Safety Guidelines detailed throughout this manual

OUTPUT PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

Output turns on momentarily, then
switches off and repeats cycle.

Remote output control not
functioning. The machine operates
normally on LOCAL control.

1. Check the input voltage. Make

sure the input voltage is correct
for the machine. See
Installation Section of this man-
ual.

2. Check or replace remote control

device. (If used)

1. Make sure the Local/Remote

switch (S3) is in the REMOTE
position.

2. The remote control device may

be faulty. Replace.

If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Lincoln Authorized Field
Service Facility.

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con-
tact your local authorized field service facility for technical troubleshooting assistance before you proceed.

CAUTION